Table 25 - TB1 Terminals
Table 26 - TB2 Terminals
Terminal Signal
Factory
Default
Description
Related
Parameter(s)
1
Analog Input 1 Comm.
(Volt)
Bipolar, differential input, ±10V, 0…20 mA, 13 bit + sign
20 k
Ω impedance at Volt; 500 Ω impedance at mA
(1)
2
Analog Input 1 (+/-)
800
3
Shield
NA
Analog Input Shield
4
Analog Input 2 Comm.
(Volt)
Bipolar, differential input, ±10V, 0…20 mA, 13 bit + sign
20 k
Ω impedance at Volt; 500 Ω impedance at mA
5
Analog Input 2 (+/-)
806
6
Analog Input 3 [NTC-] Comm.
(Volt)
Differential input, 0…10V, 10 bit (for motor control mode FOC2, this is the
temperature adaptation input).
7
Analog Input 3 [NTC+]
812
8
Shield
NA
Analog Output Shield
9
Analog Output 1 (-)
(Volt)
Bipolar, differential output, ±10V, 0…20 mA, 11 bit + sign
2 k
Ω minimum load
832, 833
10
Analog Output 1 (+)
11
Analog Output 2 (-)
(Volt)
839, 840
12
Analog Output 2 (+)
13
+10V Reference
NA
Rating: 20 mA maximum load (Recommend 5
Ω pot)
14
Reference Common
NA
15
-10V Reference
NA
16
Encoder A
NA
Normal current draw per channel: 20 mA
230-233
17
Encoder A (Not)
NA
18
Encoder B
NA
19
Encoder B (Not)
NA
20
Encoder Z
NA
21
Encoder Z (Not)
NA
22
Encoder Reference (+)
NA
12 or 5V DC power supply for primary encoder interface
Rating: 300 mA maximum
23
Encoder Reference (-)
NA
24
Encoder Shield
NA
Connection point for encoder shield
(1) The analog inputs are not isolated. However, the analog inputs can be connected in series when using current mode. Note that at 20 mA the voltage source must be capable of providing 10V DC at the
drive terminals for one drive - - 20V DC is required for two drives and 30V DC is required for three drives.
1
2
3
4
5
6
7
8
9
12
10
11
13
14
15
16
17
18
19
20
21
22
23
24
Terminal
Signal
Factory
Default
Description
Related
Parameter (s)
1
24V DC Common (-)
NA
Drive supplied 24V DC logic input power
Rating: 300 mA maximum load
2
24V DC Source (+)
NA
3
Digital Output 1
24V DC Open Collector (sinking logic)
Rating: Internal Source = 150 mA max
External Source = 750 mA
816, 847
4
Digital Output 1/2 Com
NA
Common for Digital Output 1 & 2
5
Digital Output 2
24V DC Open Collector (sinking logic)
Rating: Internal Source = 150 mA max
External Source = 750 mA
851, 852
6
Relay Output 3 (NC)
Relay contact output
Rating: 115V AC or 24V DC = 2 A max
Inductive/Resistive
856, 857
7
Relay Output 3 Com
NA
8
Relay Output 3 (NO)
9
Digital Input 1-3 Com
NA
Common for Digital Inputs 1-3
10
Digital Input 1
High speed 12V or 24V DC
(1)
, sinking
Load:15 mA at 24V DC
825
11
Digital Input 2
826
12
Digital Input 3
Load:15 mA at 24V DC sourcing
827
13
Digital Input 4-6 Com
NA
Common for Digital Inputs 4-6
14
Digital Input 4
Load: 10 mA at 24V DC sinking/sourcing
Load: 7.5 mA at 115V AC
Note: The 115 VAC Digital Inputs can withstand 2 mA of leakage current
without turning on. If an output device has a leakage current greater than 2 mA
a burden resistor is required. A 68.1
Ω resistor with a 0.5 watt rating should be
used to keep the 115 VAC output below 2 mA.
828
15
Digital Input 5
829
16
Digital Input 6
HW
Enable
830
(1) Digital Inputs 1 and 2 are configured for 12V or 24V DC via DIP switches S3-1 and S3-2, respectively. 24V DC is the default setting.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16