beautypg.com

Care and use manual, Acquity csh with cytochrome c ms conditions, Colum: acquity csh130 c – Waters Cytochrome c Digestion Standard User Manual

Page 4: See above figure for conditions, Cytochrome c digestion standard

background image

T1

T13

-T14

T14

T4

T9

-T10

T10

T8

T15

T19C

T19

T12

-T13

T12

T5+Heme

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

1.1

1.2

2

3

4

5

6

7

8

9

10

11

12 min

T1

T13

-T14

T14

T4

T9

-T10

T10

T8

T15

T19C

T19

T12

-T13

T12

T5+Heme

AU

Colum:

ACQUITY CSH130 C

18

, 1.7 µm, 2.1 x 50 mm

Part number:

186006936

Mobile phase A: 0.1% Formic Acid in 100% Water
Mobile phase B: 0.085% Formic Acid in 75% Acetonitrile
Temp.:

40 °C

Wavelength:

214 nm

Reconstitution: 200 µL of Mobile Phase A
Injection Vol:

5 µL

Run Time:

15 minutes

Gradient:

Time

Flow Rate %A %B Curve

0.00 0.200

99.0 1.0 *

5.00 0.200

79.0 21.0 6

7.50 0.200

68.6 31.4 6

11.00 0.200

5.0 95.0 6

12.50 0.200

5.0 95.0 1

15.00 0.200

99.0 1.0 1

Column: XSelect CSH C

18,

5 µm

Mixer: 50 µL

T1 T13

-T14 T14

T4

T9

-T10

T10

T8

T15

T19C

T19

T12

-T13

T12

T5+Heme

2

3

4

5

6

7

8

9

10

11

12 min

AU

0.0

0.5

1.0

1.5

Column: ACQUITY CSH C

18,

1.7 µm

Mixer: 50 µL

T1 T13

-T14

T14

T4

T9

-T10

T10

T8

T15

T19C

T19

T12

-T13

T12

T5+Heme

2

3

4

5

6

7

8

9

10

11

12 min

AU

0.0

0.5

1.0

1.5

T1

T13

-T14

T14

T4

T9

-T10

T10

T8

T15

T19C

T19

T12

-T13

T12

T5+Heme

Column: ACQUITY CSH C

18,

1.7 µm

Mixer: 380 µL

2

3

4

5

6

7

8

9

10

11

12 min

AU

0.0

0.5

1.0

1.5

Intensity

0

2 x 10

9

4 x 10

9

6 x 10

9

2

3

4

5

6

7

8

9

10

11

12 min

Column: XSelect CSH C

18,

5 µm

Mixer: 50 µL

T1 T13

-T14

T14

T4

T9

-T10

T10

T8

T15

T19C

T19

T12

-T13

T12

T5+Heme

Column: ACQUITY CSH C

18,

1.7 µm

Mixer: 50 µL

T1 T13

-T14 T14

T4

T9

-T10

T10

T8

T15

T19C

T19

T12

-T13

T12

T5+Heme

Intensity

0

2 x 10

9

4 x 10

9

6 x 10

9

2

3

4

5

6

7

8

9

10

11

12 min

T1

T13

-T14

T14

T4

T9

-T10

T10

T8 T15

T19C

T19

T12

-T13

T12

T5+Heme

T1

T13

-T14

T14

T4

T9

-T10

T10

T8 T15

T19C

T19

T12

-T13

T12

T5+Heme

Column: ACQUITY CSH C

18,

1.7 µm

Mixer: 380 µL

Intensity

0

2 x 10

9

4 x 10

9

6 x 10

9

2

3

4

5

6

7

8

9

10

11

12 min

acQuIty cSh with cytochrome c Various conditions

typical digest using acQuIty cSh130 c

18

acQuIty cSh with cytochrome c mS conditions.

See above figure for conditions.

4

[ Care and Use ManUal ]

Cytochrome c Digestion Standard