beautypg.com

5o-ring boss (orb) hydraulic fittings, Table 8.10 flare-type hydraulic tube fittings, O-ring boss (orb) hydraulic fittings – MacDon R85 Rotary Disc 16 Foot Pull-Type User Manual

Page 142

background image

MAINTENANCE AND SERVICING

Table 8.10 Flare-type hydraulic tube fittings

Torque value

1

Flats from finger

tight (FFFT)

SAE No.

Tube size

O.D. (in.)

Thread

size (in.)

Nut size

across flats

(in.)

ft·lbf

N·m

Flats

Turns

3

3/16

3/8

7/16

6

8

1

1/6

4

1/4

7/16

9/16

9

12

1

1/6

5

5/16

1/2

5/8

12

16

1

1/6

6

3/8

9/16

11/16

18

24

1

1/6

8

1/2

3/4

7/8

34

46

1

1/6

10

5/8

7/8

1

46

62

1

1/6

12

3/4

1-1/16

1-1/4

75

102

3/4

1/8

14

7/8

1-3/8

1-3/8

90

122

3/4

1/8

16

1

1-5/16

1-1/2

105

142

3/4

1/8

8.3.5 O-Ring Boss (ORB) Hydraulic Fittings

1. Inspect O-ring and seat for dirt or obvious defects.

2. On angle fittings, back off the lock nut until washer (A)

bottoms out at top of groove (B) in fitting.

3. Hand-tighten fitting until back up washer (A) or washer

face (if straight fitting) bottoms on part face (C) and
O-ring is seated.

4. Position angle fittings by unscrewing NO MORE THAN

one turn.

5. Tighten straight fittings to torque shown.

6. Tighten angle fittings to torque shown in the following

table, while holding body of fitting with a wrench.

Figure 8.9

A - Fitting

B - Lock nut

C - Washer

D - O-ring

E - Groove

F - Seat

1.

Torque values shown are based on lubricated connections as in reassembly.

169456

132

Rev. D