MacDon A40-D User Manual
Page 36

SECTION 6 OPERATION
169000 / 169040
34
Revision E
f. Route hoses (E) from windrower through
support (F) and access hole (G) in header 
frame. 
g. Remove cover on header electrical receptacle
(H).
h. Push connector onto receptacle, and turn collar
on connector to lock it in place. Try to rotate 
collar to ensure it is locked. 
i. Attach cover to mating cover on windrower
wiring harness.
j. Remove caps (if installed) from hydraulic
couplers, and clean if necessary.
k. Push hose connectors onto mating receptacles
(as shown) until collars on receptacles snap into 
lock position. 
l.
Close driveline shield before engaging header.
m. Check to ensure that hoses and electrical
harness clear tire.
n. Proceed to Section 6.6.3 Configure Reverser
Valve Jumper Hose.
6.6.1.2 M205
The M205 must be equipped with an auger drive 
basic kit, and a completion kit as shown above. 
If it is equipped, connect the hoses to the header 
in accordance with the procedure in the previous 
Section 6.6.1.1 M100, M105, M150, M155. 
If necessary, obtain the following kits from your 
MacDon Dealer, and install them in accordance 
with the instructions supplied with the kit. 
KIT DESCRIPTION
KIT NUMBER
Base Kit
B5491
Completion B5492
Coupler B5497
H
G
E
F
RETURN
CASE DRAIN
HEADER DRIVE