11 troubleshooting and fault elimination, 1 fault analysis, 1 fault analysis via the led display – Lenze ECSCExxx Power supply module User Manual
Page 119: 2 fault analysis with keypad xt emz9371bc, Troubleshooting and fault elimination, Fault analysis via the led display, Fault analysis with keypad xt emz9371bc

Troubleshooting and fault elimination
Fault analysis
Fault analysis via the LED display
11
l
119
EDBCSXE040 EN 7.0
11
Troubleshooting and fault elimination
Failures can be quickly detected and classified by means of display elements or status
messages via the MotionBus (CAN).
Display elements and status messages provide a rough classification of the trouble.
The chapter "11.2 Fault messages" (
¶ 122)contains notes on causes and deletion of
faults.
11.1
Fault analysis
11.1.1
Fault analysis via the LED display
LED
Operating status
Check
Red
Green
Off
On
Module enabled, no fault
Off
Blinking
Module inhibited (CINH), switch−on inhibit
C0183
Blinking, 1 Hz
Off
Error (TRIP) / error short−circuit braking (short−circuit
braking TRIP)
C0168/1
Blinking, 3 Hz
Off
Message
C0183, C0168/1
Blinking, 1 Hz
Blinking
Warning with inhibited module
C0183, C0168/1
Blinking, 1 Hz
On
Warning with enabled module
11.1.2
Fault analysis with keypad XT EMZ9371BC
The status messages in the display give information on the device state.
Display
Device state
Check
RDY
Ready for operation, inhibit can be set
C0183, C0168/1
IMP
Power stage inhibited
C0183, C0168/1
Imax
Maximum current reached
Fail
Fault caused by TRIP, short−circuit braking TRIP, message or
warning
C0183, C0168/1