Appendix, Codes – Lenze ECSCExxx Power supply module User Manual
Page 128

Appendix
Codes
l
128
EDBCSXE040 EN 7.0
Parameter
C0043
Designation
Reset fault message
Data type: INTEGER_32
Index: 24532
dec
= 5FD4
hex
Reset active fault message (TRIP−RESET)
^ 125
Selection list
(Lenze setting printed in bold)
Information
0 TRIP−RESET / no fault
1 Fault active
Parameter
C0050
Designation
Mains voltage (V
rms
) between phases L1−L2
Data type: INTEGER_32
Index: 24525
dec
= 5FCD
hex
Display of the mains voltage (V
rms
) between phases L1 and L2
Display range
(min. value | unit | max. value)
−16383
V
16383
Parameter
C0051
Designation
Mains voltage (V
rms
) between phases L2−L3
Data type: INTEGER_32
Index: 24524
dec
= 5FCC
hex
Display of the mains voltage (V
rms
) between phases L2 and L3
Display range
(min. value | unit | max. value)
−16383
V
16383
Parameter
C0053
Designation
DC−bus voltage (U
G
)
Data type: INTEGER_32
Index: 24522
dec
= 5FCA
hex
Display of the DC−bus voltage (U
G
)
Display range
(min. value | unit | max. value)
−32767
V
32767
Parameter
C0054
Designation
Mains current (r.m.s. value)
Data type: INTEGER_32
Index: 24521
dec
= 5FC9
hex
Display of the mains current (r.m.s. value)
Display range
(min. value | unit | max. value)
−1638.3
A
1638.3
Parameter
C0055
Designation
Voltage across the brake resistor
Data type: INTEGER_32
Index: 24520
dec
= 5FC8
hex
Display of the voltage across the brake resistor
Display range
(min. value | unit | max. value)
−32767
V
32767
Parameter
C0057
Designation
Mains frequency
Data type: INTEGER_32
Index: 24518
dec
= 5FC6
hex
Display of the mains frequency
Display range
(min. value | unit | max. value)
−3276.7
Hz
3276.7