Appendix, Codes – Lenze ECSCExxx Power supply module User Manual
Page 142

Appendix
Codes
l
142
EDBCSXE040 EN 7.0
Parameter
C0444
Designation
Status of digital outputs
Data type: UNSIGNED_16
Index: 2413
dec
= 5E43
hex
Bit coded display of the digital output status
Display range
(min. value | unit | max. value)
0x0000
0xFFFF
Bits
(read only)
Information
Bit 0 Trigger signal − +UG−relay
Bit 1 Trigger signal − −UG−relay
Bit 2 Trigger signal − IGBT
Bit 3 Trigger signal − thyristor
(LOW−active)
Bit 4 Internal signal ready for operation
(RDY)
Bit 4 = 1 (TRUE):
DC bus charged AND controller enable active (X6/DI2 =
HIGH or control word Ctrl1.Bit03 = 1)
Bit 5 Status of green LED (LOW−active)
Bit 6 Status of red LED (LOW−active)
Bit 7 Trigger signal − heatsink fan
(LOW−active)
Bit 8 IGBT gate driver reset (LOW−active)
Bit 9
Not assigned
...
Bit 15
Parameter
C0468
Designation
Function of power supply enable (X6/DI1)
Data type: INTEGER_32
Index: 24107
dec
= 5E2B
hex
Setting of power supply enable via terminal X6/DI1
Note: The parameters can only be changed if the controller is inhibited.
^ 69
Selection list
(Lenze setting printed in bold)
Information
0 Mains disconnection (slow
discharge)
1 Mains disconnection and
TRIP−RESET
2 Mains disconnection and quick
discharge (short−circuit braking)
4 Mains disconnection, quick
discharge (short−circuit braking),
and TRIP−RESET
Parameter
C0469
Designation
Function of "STOP" keypad key for ECSxE
Data type: INTEGER_32
Index: 24106
dec
= 5E2A
hex
Setting of the "STOP" keypad key function of the ECSxE power supply module
Note: The parameters can only be changed if the controller is inhibited.
Selection list
(Lenze setting printed in bold)
Information
0 No function
1 Mains disconnection (slow
discharge)
2 Quick discharge (short−circuit
braking)