5 operation with external brake resistor, Operation with external brake resistor, Commissioning – Lenze ECSCExxx Power supply module User Manual
Page 71: Stop

Commissioning
Operation with external brake resistor
l
71
EDBCSXE040 EN 7.0
6.5
Operation with external brake resistor
When an external brake resistor is used, monitoring of the internal brake resistor (OC6)
must be deactivated with C0579 = 3.
ƒ
C0579 can be found in the GDC parameter menu (
^ 75) under Short setup and
Monitoring.
(
Stop!
The device can be destroyed if the monitoring is deactivated while the internal
brake resistor is used.
Parameter
C0579
Designation
Response − monitoring of internal brake resistor (OC6)
Data type: INTEGER_32
Index: 23996
dec
= 5DBC
hex
Monitoring response of the internal brake resistor (fault message OC6)
^ 106
Selection list
(Lenze setting printed in bold)
Information
0 TRIP
3 No response
This manual is related to the following products: