1 setting the can node address and baud rate, 1 settings via dip switch, Setting the can node address and baud rate – Lenze ECSCExxx Power supply module User Manual
Page 82: Settings via dip switch, Configuring system bus (can)

Configuring system bus (CAN)
Setting the CAN node address and baud rate
Settings via DIP switch
l
82
EDBCSXE040 EN 7.0
8.1
Setting the CAN node address and baud rate
The CAN node address and baud rate can be set via the DIP switch (S1) or via C0350/C0351.
ƒ
If one of the (address) switches 2 ... 7 of the DIP switch is switched on (ON) and the
low−voltage supply is connected, the setting of the DIP switch is evaluated and
entered into C0350 (CAN node address) and C0351 (baud rate).
ƒ
If the (address) switches 2 ... 7 are switched off (OFF), the switch position is not
evaluated. The node address and the baud rate are then taken from C0350 and
C0351.
ƒ
The switch 1 of the DIP switch has no function.
8.1.1
Settings via DIP switch
ECSEE_002B
Fig. 8−2
DIP switch for node address and baud rate (all switches: OFF)