Diagnostics, Diagnostics with global drive control (gdc) – Lenze ECSCExxx Power supply module User Manual
Page 112

Diagnostics
Diagnostics with Global Drive Control (GDC)
l
112
EDBCSXE040 EN 7.0
Parameter
C0161
Designation
Current TRIP fault
Data type: INTEGER_32
Index: 24414
dec
= 5F5E
hex
Display of the current TRIP fault (TRIP, short−circuit brake TRIP)
^ 122
Parameter
C0168
Designation
Fault history buffer
Data type: INTEGER_32
Index: 24407
dec
= 5F57
hex
List of the fault messages occurred (TRIP, short circuit braking TRIP, message, warning)
^ 120
^ 122
Subcodes
Information
C0168/1
Currently active fault message
C0168/2
Last fault message
C0168/3
Second to last fault message
C0168/4
Third to last fault message
C0168/5
Fourth to last fault message
C0168/6
Fifth to last fault message
C0168/7
Sixth to last fault message
C0168/8
Seventh to last fault message
Parameter
C0178
Designation
Elapsed−hour meter
Data type: INTEGER_32
Index: 24397
dec
= 5F4D
hex
Display of the time during which the power supply module was enabled.
Display range
(min. value | unit | max. value)
−214748
h
214748
Parameter
C0179
Designation
Power−on time meter
Data type: INTEGER_32
Index: 24396
dec
= 5F4C
hex
Display of the time during which the DC bus was charged.
Display range
(min. value | unit | max. value)
−214748
h
214748
Parameter
C0200
Designation
Firmware identification (ID)
Data type: VISIBLE_STRING
Index: 24375
dec
= 5F37
hex
Display of the firmware identification (ID)
Parameter
C0201
Designation
Firmware creation date
Data type: VISIBLE_STRING
Index: 24374
dec
= 5F36
hex
Display of the firmware creation date