10 diagnostics, 1 diagnostics with global drive control (gdc), Diagnostics – Lenze ECSCExxx Power supply module User Manual
Page 110: Diagnostics with global drive control (gdc)

Diagnostics
Diagnostics with Global Drive Control (GDC)
10
l
110
EDBCSXE040 EN 7.0
10
Diagnostics
10.1
Diagnostics with Global Drive Control (GDC)
Different system values and fault messages can be read in the GDC parameter menu under
Diagnostics via the following codes:
Parameter
C0050
Designation
Mains voltage (V
rms
) between phases L1−L2
Data type: INTEGER_32
Index: 24525
dec
= 5FCD
hex
Display of the mains voltage (V
rms
) between phases L1 and L2
Display range
(min. value | unit | max. value)
−16383
V
16383
Parameter
C0051
Designation
Mains voltage (V
rms
) between phases L2−L3
Data type: INTEGER_32
Index: 24524
dec
= 5FCC
hex
Display of the mains voltage (V
rms
) between phases L2 and L3
Display range
(min. value | unit | max. value)
−16383
V
16383
Parameter
C0053
Designation
DC−bus voltage (U
G
)
Data type: INTEGER_32
Index: 24522
dec
= 5FCA
hex
Display of the DC−bus voltage (U
G
)
Display range
(min. value | unit | max. value)
−32767
V
32767
Parameter
C0054
Designation
Mains current (r.m.s. value)
Data type: INTEGER_32
Index: 24521
dec
= 5FC9
hex
Display of the mains current (r.m.s. value)
Display range
(min. value | unit | max. value)
−1638.3
A
1638.3
Parameter
C0055
Designation
Voltage across the brake resistor
Data type: INTEGER_32
Index: 24520
dec
= 5FC8
hex
Display of the voltage across the brake resistor
Display range
(min. value | unit | max. value)
−32767
V
32767
Parameter
C0057
Designation
Mains frequency
Data type: INTEGER_32
Index: 24518
dec
= 5FC6
hex
Display of the mains frequency
Display range
(min. value | unit | max. value)
−3276.7
Hz
3276.7