beautypg.com

4 reading codes with two decimal positions, 12 implemented devicenet objects – Lenze E94AYCDN User Manual

Page 82

background image

12

Implemented DeviceNet objects

12.11

Examples for reading/writing with the »Class Instance Editor«

82

Lenze · E94AYCDN communication module (DeviceNet™) · Communication Manual · DMS 5.0 EN · 02/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

12.11.4

Reading codes with two decimal positions

The current controller reset time is to be read from code C00076.
Enter the following in the input fields of the »Class Instance Editor« (fig.

[12-4]

):

• Description: Get Single Attribute (read code)
• Class: 6E (access to Lenze code)
• Instance: 4C (hex value of the code)
• Attribute: 1 (hex value of the subcode)
• Output size format: Double (4 bytes)
• Output radix format: Decimal
• Read the decimal data that are returned:

”Data received from the device”: 650  The code has the value "6.50" [ms].

[12-4] »Class Instance Editor«: Reading codes with two decimal positions