5 voltage supply, Voltage supply, Voltage supply ( 29) – Lenze E94AYCDN User Manual
Page 29: 5installation
Lenze · E94AYCDN communication module (DeviceNet™) · Communication Manual · DMS 5.0 EN · 02/2014 · TD17
29
5
Installation
5.2
Electrical installation
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.2.5
Voltage supply
The communication module is externally supplied with voltage at the 5-pole plug connector (X225)
via the DeviceNet line.
• The communication module always requires an external voltage supply.
• Communication with a standard device that is separated from the mains is not possible.
Terminal data (X225)
Note!
Use a safely separated power supply unit (SELV/PELV) in accordance with EN 61800-5-1.
Terminal
Cable colour
Description
V+
red
External voltage supply
• U = 24 V DC
• I
max
= 170 mA
V-
Black
Reference potential for external voltage supply
Area
Values
Electrical connection
Plug connector with double screw connection
Possible connections
rigid:
2.5 mm
2
(AWG 14)
flexible:
without wire end ferrule
2.5 mm
2
(AWG 14)
with wire end ferrule, without plastic sleeve
2.5 mm
2
(AWG 14)
with wire end ferrule, with plastic sleeve
2.5 mm
2
(AWG 14)
Tightening torque
0.5 ... 0.6 Nm (4.4 ... 5.3 lb-in)
Bare end
7 mm