C13855 | length of ports mapped into send pdo, C13861 | module state, C13862 | network status – Lenze E94AYCDN User Manual
Page 53: C13861, C13862, C13855/1, Rrespond to th, 11 parameter reference
![background image](/manuals/565807/53/background.png)
Lenze · E94AYCDN communication module (DeviceNet™) · Communication Manual · DMS 5.0 EN · 02/2014 · TD17
53
11
Parameter reference
11.2
Parameters of the communication module for the MXI1 slot
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13855
C13861
C13862
Parameter | Name:
C13855 | Length of ports mapped into send PDO
Data type: UNSIGNED_8
Index: 10720 = 0x29E0
Display of the total data length (in bytes) of the ports that have been mapped into the send PDO.
Display area
(min. value | unit | max. value)
0
255
Subcodes
Info
C13855/1
Length of ports mapped into send PDO
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13861 | Module state
Data type: UNSIGNED_16
Index: 10714 = 0x29DA
Display of the current module state
Selection list
(read only)
Info
0 Nonexistent
No online value available (communication module is
offline).
1 Device Self Test
The communication module is currently undergoing a
self-test.
2 Device Operational
The communication module is working perfectly.
3 Device in Standby
The communication module has not been completely
configured yet or the configuration is incorrect.
4 Minor Fault
The communication module has a fault that can be
rectified.
5 Unrecoverable Fault
The communication module is defective and must be
replaced.
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13862 | Network status
Data type: UNSIGNED_16
Index: 10713 = 0x29D9
Display of the current network status of the DeviceNet node
Selection list
(read only)
Info
0 Nonexistent
No online value available (communication module is
offline).
1 Not online
• The communication module is not supplied with
voltage via DeviceNet.
• The Duplicate MAC ID test has not been completed
yet.
2 Link OK
The communication module is working perfectly and has
established a connection to the scanner.
3 Online / Not connected
The communication module
• is working correctly;
• has performed the Duplicate MAC ID test;
• has not been connected to the scanner yet.
4 Minor Fault
The communication module has a fault that can be
rectified.
5 Critical Link Failure
The communication module cannot access the fieldbus
(e.g. Duplicate MAC ID, Bus Off, invalid baud rate etc.).
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT