For communication with the communication module, the host (PLC, scanner) must be configured
first.
Configuration for device control
For the configuration of DeviceNet, the EDS file of the communication module has to be imported
via the configuration software (e.g. »RSNetWorx« Rockwell software).
The EDS file E94AYCDN_Vxxx.eds required for configuration can be found in the download area at:
Specifying the user data length
The Servo Drives 9400 support the configuration of max. 32 process data words (max. 64 bytes) per
direction.
The user data length for consumed and produced I/O data can vary.
The user data lengths (number of process data) must be set and stored via the »Engineer« or the
scanner (
):
Note!
The direction of the flow of information must be observed!
• Consumed I/O data: process data from the scanner to the drive (device)
• Produced I/O data: process data from the drive (device) to the scanner
User data length for consumed I/O data
User data length for produced I/O data
Setting via the »Engineer« using
/
Setting via the »Engineer« using
/
The length of the ports mapped into the receipt PDO
results from the
Configuring I/O data (PDO mapping)
and is displayed in
/
. If this
length does not correspond to the user length data of the
consumed I/O data from
/
, the
DeviceNet: Consumed I/O data length is contradictory
error message will be generated
and entered as a warning in the logbook of the standard
device when the I/O connection is established.
The length of the ports mapped into the transmission
PDO results from the
and is displayed in
/
. If this length does not correspond to the user
length data of the produced I/O data from
/
, the
DeviceNet: Produced I/O data length is
contradictory [0x00C88212] ( 46)
error message will
be generated and entered as a warning in the logbook of
the standard device when the I/O connection is
established.