12 implemented devicenet objects – Lenze E94AYCDN User Manual
Page 72
12
Implemented DeviceNet objects
12.4
Connection Class (0x05 / 5)
72
Lenze · E94AYCDN communication module (DeviceNet™) · Communication Manual · DMS 5.0 EN · 02/2014 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Instance 4 ("CoS/Cyclic I/O" connection)
Services
Attribute
Service(s)
Designation
Data type
Value
1
GET
state
USINT
Status of the object
0: Nonexistent
1: Configuring
2: Waiting for connection ID
3: Established
4: Timed Out
5: Deferred Delete
2
GET
instance_type
USINT
1 (0x01)
3
GET
transportClass_trigger
BYTE
18/0 (0x12/0x00)
4
GET
produced_connection_id
UINT
Transmitting CAN identifier
5
GET
consumed_connection_id
UINT
Receiving CAN identifier
6
GET
initial_comm_characteristics BYTE
1 (0x01)
7
GET
produced_connection_size
UINT
Depending on the number of
I/O data words
8
GET
consumed_connection_size UINT
0
9
1)
GET / SET
expected_packet_rate
UINT
Connection-dependent
10
-
Not in use
-
Not defined
11
-
Not in use
-
Not defined
12
GET
watchdog_timeout_action
USINT
Defines time-out treatment
(0 = Transition to Timed Out)
13
GET
produced_connection_path_
length
UINT
7 (0x07)
14
GET
produced_connection_path
EPATH
0x20, 0x67, 0x25, 0x01, 0x00,
0x30, 0x01
15
GET
consumed_connection_path
_length
UINT
7 (0x07)
16
GET
consumed_connection_path EPATH
0x20, 0x68, 0x25, 0x01, 0x00,
0x30, 0x01
17
1)
GET / SET
production_inhibit_time
UINT
0 ... 65535 ms
(0x0 ... 0xFFFF)
Lenze setting: 0 ms (Inhibit
Time deactivated)
1) The device commands "Load Lenze setting", "Save start parameters", and "Load start parameters" do not have an
effect on this attribute.
Service code
Designation
Description
0x05
Reset
• Resetting the watchdog timer
• The communication between the scanner and the device
changes to the "Established State"
0x0E
Get_Attribute_Single
Reading an attribute
0x10
Set_Attribute_Single
Writing an attribute