8 monitoring, 1 interruption of the devicenet communication, Monitoring – Lenze E94AYCDN User Manual
Page 39: Interruption of the devicenet communication, 8monitoring
Lenze · E94AYCDN communication module (DeviceNet™) · Communication Manual · DMS 5.0 EN · 02/2014 · TD17
39
8
Monitoring
8.1
Interruption of the DeviceNet communication
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8
Monitoring
8.1
Interruption of the DeviceNet communication
An interruption of the DeviceNet communication, e.g. by a cable break or a failure of the host (PLC,
scanner), is detected by the communication module.
Responses to communication faults can be set in the DeviceNet object
or under the Monitoring tab:
Settings
Description
Idle Mode
The scanner does not transmit any I/O data if it is in idle state.
If the device (communication module) is in the idle state, the response
parameterised here (
/
) is activated in the drive.
I/O connection timeout
The data transmission of the poll or CoS/Cyclic I/O connections can be
monitored by timeouts.
The timeout values are configured within the
- instance 2 (poll I/O) or instance 4 (CoS/Cyclic I/O), attribute 9.
After the monitoring time has elapsed, the response parameterised here
(
/
) is activated in the drive.
Communication error
The device (communication module) automatically recognises
communication faults.
If a communication fault is active, the response parameterised here
(
/
) is activated in the drive.