11
Parameter reference
This chapter supplements the parameter list and the table of attributes contained in the reference
manual and in the »Engineer« online help for the Servo Drive 9400 with the parameters of the
E94AYCDN (DeviceNet) communication module.
11.1
Communication-relevant parameters of the standard device
In this chapter communication-relevant parameters of the Servo Drive 9400 are listed in
numerically ascending order.
C00615
C00636
Reference manual/»Engineer« online help for the Servo Drive 9400
Here you will find general information on parameters.
Parameter | Name:
C00615 | Resp. to imp. device config.
Data type: UNSIGNED_32
Index: 23960 = 0x5D98
Response for an impermissible device configuration
Selection list
1 Fault
3 Quick stop by trouble
4 Warning Locked
6 Information
0 No Response
Subcodes
Lenze setting
Info
C00615/1
0: No Response
Reserved
C00615/2
1: Fault
Response to non-permissible module in MXI1
C00615/3
1: Fault
Response to non-permissible module in MXI2
C00615/4
0: No Response
Reserved
C00615/5
0: No Response
Reserved
Read access Write access CINH PLC-STOP No transfer
Parameter | Name:
C00636 | Resp. to new module in MXI1
Data type: UNSIGNED_32
Index: 23939 = 0x5D83
Response for the case where a new module has been plugged into slot 1 of the standard device.
Selection list
(Lenze setting printed in bold)
1 Fault
6 Information
5 Warning
4 Warning Locked
3 Quick stop by trouble
0 No Response
Read access Write access CINH PLC-STOP No transfer