2 electrical installation, 1 wiring of the devicenet, Electrical installation – Lenze E94AYCDN User Manual
Page 22: Wiring of the devicenet, Wiring of the devicenet ( 22), 5installation
![background image](/manuals/565807/22/background.png)
5
Installation
5.2
Electrical installation
22
Lenze · E94AYCDN communication module (DeviceNet™) · Communication Manual · DMS 5.0 EN · 02/2014 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.2
Electrical installation
5.2.1
Wiring of the DeviceNet
For communication with the scanner and all further components, Servo Drives 9400 have to be
assembled with communication modules.
A DeviceNet line can have a maximum number of 64 nodes. The nodes include ...
• the scanner;
• the connected drives (devices);
• all other components which take part in communication.
For integrating the communication modules in the DeviceNet line, a PC/laptop with installed
configuration software (e. g. »RSNetWorx«) is required. The PC/laptop solely serves to the
configuration and diagnostics and therefore is not a DeviceNet node.
Documentation relating to the standard device, host (PLC, scanner), system/machine
Observe the notes and wiring instructions contained in this documentation.