3 assembly class (0x04 / 4), Assembly class (0x04 / 4), 12 implemented devicenet objects – Lenze E94AYCDN User Manual
Page 69
Lenze · E94AYCDN communication module (DeviceNet™) · Communication Manual · DMS 5.0 EN · 02/2014 · TD17
69
12
Implemented DeviceNet objects
12.3
Assembly Class (0x04 / 4)
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
12.3
Assembly Class (0x04 / 4)
This object contains some information relating to input and output data of the scanner.
Instance 768 ... 832 (scanner input data)
Instance 833 ... 897 (scanner output data)
Services
Attribute
Service(s)
Designation
Data type
Instance/value
3
1)
GET / SET
Data
Array of BYTE
Instance 768 (0x300):
0 bytes to the scanner
Instance 769 (0x301):
1 byte to the scanner
Instance 770 (0x302):
2 bytes to the scanner
Instance 771 (0x303):
3 bytes to the scanner
...
Instance 832 (0x340):
64 bytes to the scanner
1) The device commands "Load Lenze setting", "Save start parameters", and "Load start parameters" do not have an
effect on this attribute.
Attribute
Service(s)
Designation
Data type
Instance/value
3
GET / SET
Data
Array of BYTE
Instance 833 (0x341):
0 bytes from the scanner
Instance 834 (0x342):
1 byte from the scanner
Instance 835 (0x343):
2 bytes from the scanner
Instance 836 (0x344):
3 bytes from the scanner
...
Instance 897 (0x381):
64 bytes from the scanner
1) The device commands "Load Lenze setting", "Save start parameters", and "Load start parameters" do not have an
effect on this attribute.
Service code
Designation
Description
0x0E
Get_Attribute_Single
Reading an attribute
0x10
Set_Attribute_Single
Writing an attribute