Parameter reference

11.3

Parameters of the communication module for the MXI2 slot

62

Lenze · E94AYCDN communication module (DeviceNet™) · Communication Manual · DMS 5.0 EN · 02/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C14884

C14885

C14900

C14901

C14902

Parameter | Name:

C14884 | Data length of produced I/O data

Data type: UNSIGNED_8

Index: 9691 = 0x25DB

Setting of the data length (in bytes) of the I/O data to be transmitted by the device via DeviceNet.

Note:

• If the data length is changed, the DeviceNet scanner will be informed about this change (produced data size).

• If the data length is reduced, it must be checked before if the intended data length is sufficient for the

application.

• If the data length of the produced I/O data does not correspond to the length of the mapped ports which is

specified by the drive via PDO mapping, the

DeviceNet: Produced I/O data length is contradictory [0x00C88212]

( 46)

error message is generated and entered as a warning into the logbook of the standard device.

• If the number of produced I/O data deviates from the Lenze setting (4 bytes), the "Automap on Add" function in

the scanner configuration dialog of the »RSNetWorx« software has to be deactivated and the number of the

process data words has to be adapted via the "Edit I/O parameters" button.

Setting range

(min. value | unit | max. value)

Lenze setting

0

64 4

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C14885 | Delete process data

Data type: UNSIGNED_8

Index: 9690 = 0x25DA

Setting of the process data which must be further processed by the drive to maintain internal communication if the

current network status (

C14862

) is "Minor Fault" or "Critical Link Failure".

Selection list

(Lenze setting printed in bold)

0 Use of the latest scanner I/O data
1 I/O data are set to a value of '0'

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C14900 | Firmware: Product type

Data type: VISIBLE_STRING

Index: 9675 = 0x25CB

Display of the product type (string with a length of 8 bytes)

The following identification code will be output: "E94AFCDN"

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C14901 | Firmware: Compilation date

Data type: VISIBLE_STRING

Index: 9674 = 0x25CA

Display of the firmware compilation date (string with a length of 20 bytes)

The date ("MMM DD YYYY") and time ("hh:mm:ss") will be provided, e.g. "Mar 21 2005 12:31:21".

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C14902 | Firmware: Version

Data type: VISIBLE_STRING

Index: 9673 = 0x25C9

Display of the firmware version (string with a length of 5 bytes)

The identification code will be output, e.g. "01.11".

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT