beautypg.com

6 special device functions – JUMO 709062 TYA 202 - Three-Phase Power Controller Operating Manual User Manual

Page 82

background image

6 Special device functions

80

2012-12-31/00561073 [SCR power switch TYA202]

This results in double the current for the SCR power controller.

Old = old state of the heating element R

old

=

New = new condition of the heating element

The relationship is illustrated by the following formula:

P control is also used for free-running economy circuits running off a 3-phase
supply network.

Which
operating mode
is suitable for
which load?

R

old

4

---------

P

new

U

new

I

new

U

old

2

---------

2I

old

U

old

I

old

P

old

=

=

=

=

(12)

Operating mode

Resistive load

Inductive
load

TC constant

TC positive

TC nega-
tive

Long-
term ag-
ing

Burst-firing mode

X

Burst-firing mode with

α

start

X

X

Burst-firing mode with
current limiting

X

X

X

Subordinate control

U

2

X

X

X

I

2

X

X

P

X

X