Menus and Configuration
15
Assign Station Master
One SmartPack in a system with wall stations installed should be configured as the “Station
Master”. The station master tracks and updates button LED states for connected wall
stations when preset or sequence changes occur. In addition the station master sends host
messages to other SmartLink enabled SmartPack dimmer packs in the system.
For systems without wall stations, there is no requirement to configure a station master.
Default functionality for pack to pack synchronization is that the last SmartPack or
SmartSwitch updated in the system acts as the station master and send its host messages
to the other products in the system.
Step 1:
Scroll to [Stations] and press .
Step 2:
Scroll to [Station Master] and press .
• If the SmartPack you are configuring is to be the Station Master, scroll to
[Enable] and press .
• If the SmartPack you are configuring is not the Station Master, scroll to
[Disable] and press .
Remote Record
Enable “Remote Record” within the station master for user ability to record presets from
SmartLink wall stations.
Disable “Remote Record” within the station master to lock-out the ability to record presets
from SmartLink wall stations.
Step 1:
From the face panel of the station master, scroll to [Stations], press .
Step 2:
Scroll to [Remote Record], press .
Step 3:
For the ability to record a preset from a SmartLink wall station scroll to [Enable]
and press .
• After enabling “Remote Record”, the user has the option to set dimmer
levels to a desired look (via the test menu or other DMX control device) and
record that look to a specific preset via the wall station.
Preset from a Wall Station” on page 22.
Step 4:
If the ability to record a preset from a wall station is not desired scroll to [Disable]
and press .
• If disabled, preset recording must be accomplished from the face panel of
the station master.
N o t e :
ETC recommends configuring the SmartPack with the LinkPower supply installed
and wall stations connected as the “Station Master”.