6 ping watchdog – AirLive AirMax5 User Manual
Page 79
5. Web Management2: System Configuration and Status
AirLive AirMax5 User’s Manual
72
Assign a specific name and IP address for your SNMP trap manager:
A trap manager is a remote SNMP management station where special SNMP trap
messages are generated (by the router) and sent to in the network.
You can define trap managers in the system.
You can add a trap manager by entering a name, an IP address, followed by pressing
the ADD button.
You can delete a trap manager by selecting the corresponding entry and press the
DELETE SELECTED button.
To enable a trap manager, check the Enable box in the corresponding entry; to disable
it, un-check the Enable box.
5.1.6 Ping Watchdog
System Configuration -> Ping Watchdog
The Ping Watchdog will ping remote IP addresses to make sure the wireless connection is
active, if not, it can either reconnect or reboot. To prevent the AP from power recycling,
the PING watchdog will start 10 minutes after power up to prevent power recycle problem.
PING Frequency means: "How often the CPE will PING". For example, it will PING
once every "1" minute.
Fail Tries means "How many times fails before the CPE will judge the PING
failed". For example "2" means the CPE will reconnect if the PING doesn't respond for
2 times.
When you set the Ping Frequency to every "2" minutes and Fail Tries to "2". It means the
CPE will ping every 2 minutes, after the second failure, it will reconnect.