Torque chart (metric fasteners - sheet 7 of 7) -14, Class 12.9 socket head cap screws m6 and above – JLG 340AJ Service Manual User Manual
Page 30
SECTION 1 - SPECIFICATIONS
1-14
– JLG Lift –
3121259
Figure 1-8. Torque Chart (METRIC Fasteners - Sheet 7 of 7)
Size
PITCH
Tensile
Stress
Area
Clamp Load
See Note 4
Torque
(Dry or Loctite®
263
TM
)
K = .17
Torque
(Lub OR Loctite®
242
TM
or 271
TM
OR Vibra-TITE
TM
111 or 140)
K = .16
Torque
(Loctite® 262
TM
OR Vibra-TITE
TM
131)
K = .15
Sq mm
kN
[N.m]
[N.m]
[N.m]
3
0.5
5.03
3.5
0.6
6.78
4
0.7
8.78
5
0.8
14.20
6
1
20.10
12.5
13
12
11
7
1
28.90
18.0
21
20
19
8
1.25
36.60
22.8
31
29
27
10
1.5
58.00
36.1
61
58
54
12
1.75
84.30
52.5
105
100
95
14
2
115
71.6
170
160
150
16
2
157
97.8
265
250
235
18
2.5
192
119.5
365
345
325
20
2.5
245
152.5
520
490
460
22
2.5
303
189.0
705
665
625
24
3
353
220.0
900
845
790
27
3
459
286.0
1315
1235
1160
30
3.5
561
349.5
1780
1680
1575
33
3.5
694
432.5
2425
2285
2140
36
4
817
509.0
3115
2930
2750
42
4.5
1120
698.0
4985
4690
4395
CLASS 12.9 SOCKET HEAD CAP SCREWS
M6 AND ABOVE*
4. CLAMP LOAD LISTED FOR SHCS IS SAME AS GRADE 8 OR CLASS 10.9 AND DOES NOT
REPRESENT FULL STRENGTH CAPABILITY OF SHCS. IF HIGHER LOAD IS REQUIRED,
ADDITIONAL TESTING IS REQUIRED.
*3. ASSEMBLY USES HARDENED WASHER OR FASTENER IS PLACED AGAINST PLATED
STEEL OR RAW ALUMINUM
NOTES: 1. THESE TORQUE VALUES DO NOT APPLY TO CADMIUM PLATED FASTENERS
2. ALL TORQUE VALUES ARE STATIC TORQUE MEASURED PER STANDARD AUDIT
METHODS TOLERANCE = ±10%
NO. 5000059 REV. J
Magni Coating (Ref 4150701)*