SECTION 1 - SPECIFICATIONS

1-6

– JLG Lift –

3121259

3.

Hydraulic Tank

Lube Point(s) - Fill Cap
Capacity - 24.8 Gal. (93.9 L), 20.6 Gal. (77.9 L) to Full

Level; 17.8 Gal (67.4 L) to Low Level

Lube - HO
Interval - Check Level daily; Change every 2 years or

1200 hours of operation.

Comments - On new machines, those recently over-

hauled, or after changing hydraulic oil, operate all sys-
tems a minimum of two complete cycles and recheck
oil level in reservoir.

4.

Hydraulic Tank Return Filter and Breather

Interval - Change after first 50 hrs. and every 6 months

or 300 hrs. thereafter.

Comments - For breather element, twist top to replace.

5.

Wheel Drive Hub

Lube Point(s) - Level/Fill Plug
Capacity - 25.5 oz. (0.75 L)(1/2 Full)
Lube - EPGL
Interval - Check level every 3 months or 150 hrs of oper-
ation; change every 2 years or 1200 hours of operation

6.

Oil Change with Filter - Kubota

Lube Point(s) - Fill Cap/Spin-on Element
Capacity - 5.4 Quarts (5.1 L) w/Filter
Lube - EO
Interval - Check level daily; change every 500 hours or

six months, whichever comes first. Adjust final oil
level by mark on dipstick.

OIL LEVEL CHECK