JLG 340AJ Service Manual User Manual
Page 270

SECTION 6 - JLG CONTROL SYSTEM
6-26
– JLG Lift –
3121259
LIFT
Accel
0.0 - 5.0sec
2.0sec
Decel
0.0 - 5.0sec
1.0sec
Min up
250 - 1400mA
400mA
Max Up
250 - 1400mA
1250mA
Creep Up
250 - 1400mA
525mA
Min Down
250 - 1400mA
400mA
Max Down
250 - 1400mA
850mA
Creep Down
250 - 1400mA
500mA
Soft Down
250 - 1400mA
500mA
TELESCOPE
Accel
0.0 - 5.0sec
1.2sec
Decel
0.0 - 5.0sec
0.5sec
Min In
250 - 1400mA
400mA
Max In
250 - 1400mA
1250mA
Creep In
250 - 1400mA
675mA
Min Out
250 - 1400mA
400mA
Max Out
250 - 1400mA
1250mA
Creep Out
250 - 1400mA
675mA
JIB LIFT
Accel
0.0 - 5.0sec
1.2sec
Decel
0.0 - 5.0sec
0.5sec
Min Up
250 - 1400mA
400mA
Max Up
250 - 1400mA
1075mA
Creep Up
250 - 1400mA
575mA
Min Down
10 - 70%
32%
Max Down
10 - 70%
53%
Creep Down
10 - 70%
48%
PLATFORM LEVEL
Accel
0.0 - 5.0sec
0.0sec
Decel
0.0 - 5.0sec
0.0sec
Min Up
250 - 1400mA
400mA
Max Up
250 - 1400mA
1250mA
Creep Up
250 - 1400mA
550mA
Min Down
250 - 1400mA
400mA
Max Down
250 - 1400mA
1250mA
Creep Down
250 - 1400mA
550mA
PLATFORM ROTATE
Accel
0.0 - 5.0sec
0.0sec
Decel
0.0 - 5.0sec
0.0sec
Min Left
250 - 1400mA
400mA
Max Left
250 - 1400mA
1250mA
Creep Left
250 - 1400mA
1250mA
Min Right
250 - 1400mA
400mA
Max Right
250 - 1400mA
1250mA
Creep Right
250 - 1400mA
1250mA
Table 6-6. Machine Model Adjustment
Adjustment
Adjustment Ranges
Default Setting