Fig . 1 dimensional da ta – Burnham Series 5B User Manual

Page 6

background image

6

FIG

. 1

DIMENSIONAL

DA

TA

Boiler Size

Jacket Overall Length

‘A’

Draft Hood Height, Size and Location

Top Supply

and Rear Return

Location

Supply Conn. Qty & Size

Return

Conn.

Qty

. & Size

Gas Conn. Size Nat. & Propane

No. & Dia. of Flue Outlets

Approx. Shipping W

eight (LB.)

‘B’

Dia.

‘C’

Dia.

‘D’

Dia.

‘E’

Dia.

‘F’

‘G’

‘H’

‘J’

‘K’

‘M’

‘N’

5006B

34

9

---

---

---

---

---

---

17

19-3/4

---

---

(2) 3

(2) 3

1

(1) 9

1160

5007B

39-3/8

10

---

---

---

---

---

---

19-3/4

32-1/4

---

---

(2) 3

(2) 3

1

(1) 10

1340

5008B

44-3/4

12

---

---

---

---

---

---

22-3/8

38-3/8

---

---

(2) 3

(2) 3

1

(1) 12

1525

5009B

50-1/4

12

---

---

---

---

---

---

25-1/8

43-3/4

---

---

(2) 3

(2) 3

1-1/4**

(1) 12

1720

5010B

55-3/4

12

---

---

---

---

---

---

27-7/8

49-1/4

---

---

(2) 3

(2) 3

1-1/4

(1) 12

1895

501

1B

61-1/8

9

9

---

---

27-1/4

---

---

17

54-3/4

---

---

(2) 3

(2) 3

1-1/4

(2) 9

2085

5012B

66-1/2

9

10

---

---

29-7/8

---

---

19-3/4

60-1/8

---

---

(2) 3

(2) 3

1-1/4

(1) 9, (1) 10

2280

5013B

72

10

10

---

---

32-5/8

---

---

19-3/4

65-1/2

---

---

(2) 3

(2) 3

1-1/4

(2) 10

2460

5014B

77-1/2

10

12

---

---

35-3/8

---

---

22-3/8

71

---

---

(2) 3

(2) 3

1-1/4

(1) 10, (1) 12

2640

5015B

82-7/8

12

12

---

---

38

---

---

22-3/8

38-1/4

38-1/4

---

(3) 3

(2) 3, (1) 2-1/2

(2) 1*

(2) 12

2870

5016B

88-1/4

12

12

---

---

40-3/4

---

---

25-1/8

38-1/4

43-5/8

---

(3) 3

(2) 3, (1) 2-1/2

(1) 1, (1) 1-1/4*

(2) 12

3070

5017B

93-3/4

12

12

---

---

43-1/2

---

---

25-1/8

43-5/8

43-5/8

---

(3) 3

(2) 3, (1) 2-1/2

(2) 1-1/4*

(2) 12

3265

5018B

99-1/4

12

12

---

---

46-1/4

---

---

27-7/8

43-5/8

49-1/8

---

(3) 3

(2) 3, (1) 2-1/2

(2) 1-1/4*

(2) 12

3445

5019B

104-5/8

12

12

---

---

49

---

---

27-7/8

49-1/8

49-1/8

(3) 3

(2) 3, (1) 2-1/2

(2) 1-1/4*

(2) 12

3620

5020B

11

0

9

9

12

---

27-1/4

38

---

27-7/8

54-1/2

49-1/8

---

(3) 3

(2) 3, (1) 2-1/2

(2) 1-1/4*

(2) 9, (1) 12

3810

5021B

115-1/2

9

10

12

---

29-7/8

40-3/4

---

27-7/8

27-3/8

32-5/8

49-1/8

(4) 3

(2) 3, (2) 2-1/2

(2) 1-1/4*

(1) 9, (1) 10, (1) 12

4005

5022B

121

10

10

12

---

32-5/8

40-3/4

---

27-7/8

32-3/4

32-5/8

49-1/8

(4) 3

(2) 3, (2) 2-1/2

(2) 1-1/4*

(2) 10, (1) 12

4185

5024B

131-3/4

9

10

10

10

29-7/8

32-5/8

32-5/8

19-3/4

27-3/8

65-1/4

32-3/4

(5) 3

(2) 3, (3) 2-1/2

(2) 1-1/4*

(1) 9, (3) 10

4530

5026B

142-3/4

10

12

10

10

35-3/8

35-3/8

32-5/8

19-3/4

32-3/4

70-3/4

32-3/4

(5) 3

(2) 3, (3) 2-1/2

(2) 1-1/4*

(3) 10, (1) 12

4895

* Dual Manifolds - 5015B thru 5026B **1” - USA

- EI

NOTE

1.

5006B

THRU

5014B

BOILERS

REQUIRE

SINGLE GAS

TRAIN LOCA

TION ON

LEFT

END OF BOILER (ST

ANDARD)

GAS

TRAIN MA

Y

BE RELOCA

TED

TO RIGHT

END OF BOILER (EXCEPT

5012B

AND

5014B

BOILERS).

2.

5015B

THRU

5026B

BOILERS

REQUIRE

DUAL

GAS TRAINS.

3.

GAS SUPPL

Y

PRESSURE, IN

W

.C.

NA

TURAL

GAS

MAXIMUM: 14”

W

.C.

MINIMUM: 5.5”

W

.C.

(5009B

AND

501

1B

THRU

5014B

AND

5020B

THRU

5026B)

MINIMUM: 5”

W

.C.

(5006B

THRU

5008B

AND

5010B,

5015B

THRU

5019B)

LP

GAS:

MAXIMUM: 14”

W

.C.

MINIMUM: 1

1”

W

.C.

4.

W

ATER BOILERS - MAXIMUM DESIGN

WORKING

PRESSURE:

50

PSI.

5.

STEAM BOILER - MAXIMUM DESIGN WORKING PRESSURE: 15 PSI.

6.

DIMENSIONS

IN

INCHES