Canadian equipment check list – Burnham Series 5B User Manual

Page 5

background image

5

BOILER SIZE

5006B

5007B

5008B

5009B

5010B

5011B

5012B

5013B

5014B

5015B

5016B

5017B

5018B

5019B

5020B

5021B

5022B

5024B

5026B

CARTONS, PACKAGES OR BUNDLES

7 S

Steam Trim Carton (Steam Boilers Only - Includes PA404 Pressure Limit Control) 4 Sizes - One Per Boiler

1

1

1

1

---

---

---

---

---

---

---

---

---

---

---

---

---

---

---

---

2

---

---

---

1

1

1

---

---

---

---

---

---

---

---

---

---

---

---

---

3

---

---

---

---

---

---

1

1

1

1

1

1

1

1

1

---

---

---

---

4

---

---

---

---

---

---

---

---

---

---

---

---

---

---

---

1

1

1

1

67 Bc-2

Low Water Cut-off Carton (Steam Boilers Only) One Per Boiler

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

7 W

Water Trim Carton (Water Boilers Only - Includes L4006A Temp. Limit Control) 3 Sizes - One Per Boiler

2

1

1

1

1

1

1

---

---

---

---

---

---

---

---

---

---

---

---

---

3

---

---

---

---

---

--

1

1

1

1

1

1

1

1

1

1

1

1

1

4

---

---

---

---

---

---

---

---

---

---

---

---

---

---

---

---

---

1

1

64

Low Water Cut-off Carton (Water Boilers Only) One Per Boiler

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

U

8

Complete Jacket Carton Assembly - One Per Boiler

c

9

1

Gas Train Cartons (By Gas) 2 Sizes - One or Two Per Boiler

c

9

1

1

1

1

---

---

---

---

---

---

2

1

---

---

---

---

---

---

---

---

c

9

2

---

---

---

1

1

1

1

1

1

---

1

2

2

2

2

2

2

2

2

THeRM.

Controls Carton(s) (Manual Ignition. - 100% Shutoff - 24V.) 1 Size - One or Two Per Boiler

Natural

1

1

1

1

1

1

1

1

---

2

2

2

2

2

2

2

2

2

---

OP

Controls Carton(s) (By Gas) (Manual Ign. - 100% Shutoff - 24V. - Nat. - 120V. LP) 1 Size - One or Two Per Boiler

Natural

---

---

---

---

---

---

---

---

1

---

---

---

---

---

---

---

---

--

2

Propane

1

1

1

1

1

1

1

1

1

2

2

2

2

2

2

2

2

2

2

U

HcP

1

Plain Heater Cover Plate (Not furnished on Water Boiler Ordered With Two Tankless Heaters) One Per Boiler

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

U

HcP

2

Tapped (¾” NPT) Heater Cover Plate (Not Furnished on Water Boiler Ordered With Tankless Heater(s) One Per Boiler

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

CANADIAN

EQUIPMENT CHECK LIST

INSPECT SHIPMENT carefully for any signs of damage. All equipment is carefully manufactured, inspected and packed.

Our responsibility ceases upon delivery of Boiler to carrier in good condition. Any claims for damage or shortage in

shipment must be filed immediately against the carrier by the consignee. No claims for variances or shortages will be

allowed by Boiler Manufacturer, unless presented within sixty (60) days after receipt of equipment.

SECTION I - EQUIPMENT CHECK LIST - Page 2
SECTION II - GENERAL INFORMATION - Page 7
SECTION III - INSTALLATION INSTRUCTIONS - Page 8
SECTION IV - OPERATION - Page 41
SECTION V - SERVICE - Page 65
SERVICE RECORDS - Page 72
SECTION VI - REPAIR PARTS - Page 73

APPENDIX A - FIGURES - Page 105

APPENDIX B - TABLES - Page 108

SecTiON i – eQUiPMeNT cHecK LiST (continued)