3 [status notification setting, Status notification setting] -16, Status notifica – Konica Minolta BIZHUB 223 User Manual
Page 210: Tion setting

bizhub 423/363/283/223
10-16
10.5
Reporting the status of this machine (by E-mail)
10
10.5.3
[Status Notification Setting]
In the administrator mode of PageScope Web Connection, select [Maintenance] ö [Status Notification Set-
ting] ö [E-mail Address] ö [Edit].
[SMTP Server Ad-
dress]
Enter the SMTP server address.
Format: *.*.*.* (Asterisk * can be 0 to 255)
If the DNS server has already been configured, you can
enter the host name instead.
When using IPv6, you can specify the IPv6 address.
Server address
[Port Number]
Enter a port number.
Default setting: 25
Server port number
[Connection Time-
out]
Specify the timeout period for a communication with a
server.
[Max Mail Size]
Select whether to limit the size of an E-mail to be sent.
[Server Capacity]
Enter the SMTP server capacity. A mail that exceeds the
upper limit of the server capacity will be discarded.
If an E-mail is divided, this setting is made invalid.
Server reception limit
[Admin. E-mail Ad-
dress]
Displays the E-mail address of the administrator.
Register the administrator's E-mail address in [System
Settings]ö[Machine Setting] if it is not registered.
[Binary Division]
Select this check box to divide an E-mail.
If the E-mail software that received an E-mail does not
have a restoration function, you may not be able to read
the E-mail.
Restoration function
of E-mail software
[Divided Mail Size]
Enter the divided mail size to divide an E-mail.
Server reception limit
Item
Description
Prior check
Item
Description
Prior check
[Notification Ad-
dress]
Enter the destination E-mail address.
Notification address
[Replenish Paper
Tray]
Sends a notification when the paper tray is empty.
[JAM]
Sends a notification when a page has been jammed.
[PM Call]
Sends a notification when the periodical inspection is re-
quired.
[Replace Staples]
Sends a notification when there are no staples remaining.