AMX MVP-5100 User Manual
Page 130
Programming
122
MVP-5100/5150 Modero Viewpoint Touch Panels
"^" Button Commands (Cont.)
^BVL
Log-On/Log-Off
the computer
control
connection.
Syntax:
"'^BVL-
Variable:
variable text address range = 1 - 4000.
connection = 0 (Log-Off connection) and 1 (Log-On connection).
Example:
SEND_COMMAND Panel,"'^BVL-500,0'"
Logs-off the computer control connection of the button.
^BVN
Set the computer
control remote
host for the
specified address.
Syntax:
SEND_COMMAND
Variables:
variable text address range = 1 - 4000.
remote host = 1 - 50 ASCII characters.
Example:
SEND_COMMAND Panel,"'^BVN-500,191.191.191.191'"
Sets the remote host to '191.191.191.191' for the specific computer control button.
^BVP
Set the network
password for the
specified address.
Syntax:
"'^BVP-
Variable:
variable text address range = 1 - 4000.
network password = 1 - 50 ASCII characters.
Example:
SEND_COMMAND Panel,"'^BVP-500,PCLOCK'"
Sets the password to PCLOCK for the specific PC control button.
^BVT
Set the computer
control network
port for the
specified address.
Syntax:
"'^BVT-
Variable:
variable text address range = 1 - 4000.
network port = 1 - 65535.
Example:
SEND_COMMAND Panel,"'^BVT-500,5000'"
Sets the network port to 5000.
^BWW
Set the button
word wrap feature
to those buttons
with a defined
address range.
By default, word-wrap is Off.
Syntax:
"'^BWW-
Variable:
variable text address range = 1 - 4000.
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons
1 = Off state and 2 = On state).
word wrap = (0=Off and 1=On). Default is Off.
Example:
SEND_COMMAND Panel,"'^BWW-500,1,1'"