Writing a Configuration
46
6. Select Use the following IP Address, and fill in the details as shown in
7. Click OK.
Figure 59: Internet Protocol (TCP/IP) Properties Window
8.2 Connecting the ETHERNET Port via a Network Hub (Straight-
Through Cable)
You can connect the Ethernet port of the RC device to the Ethernet port on a
network hub or network router, via a straight-through cable with RJ-45
connectors.
9 Writing a Configuration
Once your configuration is ready, you can write it to the device, via the “Write
Configuration” button.
Note that if the room controller is defined as a:
• Master (standalone), the configuration is written directly to the device
• Auxiliary device (for example, the room controller is connected to the
SV-551), the configuration is written to the SV-551
In case you have written the configuration to a standalone device and it is now
connected as an auxiliary device to the SV-551, you have to write the
configuration once again after defining the device as an auxiliary device.
To write a configuration to the device, do the following:
1. Connect the PC to the: