beautypg.com

Festo Фиксаторы KPE User Manual

Page 29

background image

DNCKE-.../KEC-...

Festo DNCKE-.../KEC-... 0204NH English

29

Commissioning – carrying out

S

Please observe the limits for all loadings.

Setting the speed and the end position
cushioning:

S

Tighten the screws of the upstream one-
way flow control valves (A) and the end
position cushioning (B) on the DNCKE-...:
– at first completely
– then loosen approximately one turn.

S

Pressurize:
– the complete system slowly.

To do this use safety start-up valve type HEL-... .

– the cylinders at first simultaneously on both compressed air connections 1

(only with DNCKE-...).
This will prevent movement against an unpressurized cylinder chamber.

– the clamping unit at compressed air connection 2 with at least 3.8 bar.

The piston rod then moves slowly into the extended end position.

S

Start a test run at low frequency and at low impact speed.

S

Repeat the test run increasing the speed step-by-step until the operating
speed is reached.
If set correctly, the work load should reach the end position without striking
hard against it.

S

During the test run check whether these settings on the clamping unit need to
be modified:
– The speed of the work load
– The end position cushioning
– The clamping force (if the system is designed for this, by pressurizing the

cylinder briefly with maximum pressure (10 bar); the clamping rod must not
break through.
Remedy if the clamping rod breaks through:
Adjust the clamping unit again in accordance with the chapter “Commis-
sioning – preparation”).

S

Conclude the test run.

Fig. 26

(B)

(A)

This manual is related to the following products: