4-46

5708009-C

Advanced Energy

®

8

setpoint

Specifies the output setpoint level for
whatever method of output regulation has
been selected. Accepts a value of 0 to 8000
W (for the 8 kW option) or 0 to 10000 W (for
the 10 kW option) when forward or load
power regulation is selected. Regular units
report in units of watts. HALO units report in
units of tenths of watts.

2 data bytes
16-bit value

1

9

max ext

feedback

Specifies the external feedback value that
corresponds to 10 V on the User port;
requires data bytes arranged as follows:

First/second byte = a 16-bit value in the
range of 500 to 5000.

Third byte = the number of decimal
places (0 to 4) used to display the
external feedback signal on the operator
panel.

3 data bytes
16-bit value

8-bit value

11

select
active
target

Specifies which target is active; accepts a
value of 1 to 4. (Readback command is 156.)

1 data byte

8-bit value

1

12

set target

life

Sets the life (in kWh) of the target you
specify. Requires five data bytes arranged as
follows:

First byte = the target number

Second, third, fourth, fifth bytes = target
life in kWh

Note: A decimal is implied—to get 1 kWh,

send a value of 100.

(Readback command is 157.)

5 data bytes

8-bit value

32-bit value

1

14

control

transfer

Sets the active control mode of the generator;
possible choices are: 2 = host, 4 = User port
(analog).

1 data byte

8-bit value

1

15

out-of-

setpoint

timer

Specifies how long the generator can produce
output that is not equal to the programmed
setpoint level. Accepts a value of 0 to 599 s.
(Readback command is 184.)

2 data bytes
16-bit value

1

Table 4-6. Host Port Commands for RS-232 with AE Bus (Continued)

Command

Description

Number of

Host Data

Bytes

Number of

Response

Data Bytes