beautypg.com

Reflected power limit, Dissipation limit, Maximum pa dissipation—non-latching alarm led – Apex Digital 5708009-C User Manual

Page 40: Low/high line bus, Bus voltage outside spec window—latching alarm led, Over-temperature, Output power range, Output power regulation accuracy, Into 50 w non-reactive load, Into 3:1 vswr non- reactive load

background image

3-8

5708009-C

Advanced Energy

®

Output protection—Apex generators sense and employ several parameters for protection

Reflected power limit

20% of maximum forward power for units rated for less
than 5500 W. 1000 W for 5500 W units. (PIN position 2
defines the maximum forward power rating for the unit.)

Dissipation limit

Maximum PA dissipation—non-latching alarm LED

Low/high line bus

Bus voltage outside spec window—latching alarm LED

Over-temperature

Over-temp condition—latching alarm LED preceded by
non-fault warning (user setting).

Output power range

All generators except the HALO will allow setpoints
between 1% and 100% of full scale. The exception is the
HALO 1.5k generator depicted by “L” in position 2 of the
PIN number. This allows setpoints from 5 watts to 1500
watts.

Output power regulation accuracy

Into 50

Ω non-reactive load

± 1% of setpoint or ± 0.1% of full-rated output,
whichever is greater (all PIN position 2 options but K
and L)

≤ ±1% of setpoint or 0.25 W, whichever is greater
(PIN position 2, option K & L)

Into 3:1 VSWR non-
reactive load

± 3% of setpoint (load power regulation), over all load
phase angles, or ± 0.25% of full-rated output, which ever is
greater

Load regulation as a function
of line regulation

Less than 0.1% change in output power for 10% change in
ac line voltage

Load regulation as a function of temperature—(performance in accordance with the output
power regulation accuracy)

Ambient air temperature
range

+5

°

C to +40

°

C

Cooling water temperature
range

+5

°

C to +35

°

C

Spurious outputs—Referenced to fundamental signal at full-rated output when operated in a
50

Ω non-reactive load

Harmonic related

-40 dBc

Non-harmonic related

-50 dBc

Table 3-3. Output Specifications (Continued)

Description

PIN Option and Specification