E050
DeviceNet
Error

DeviceNet error

Verify DeviceNet
cable is connected

E051
Profibus Watch
Dog expired

PROFIBUS watch dog expired

Have the master
reestablish
communications and
send a “master reset”
to clear the error. See
“Profibus Watch Dog
Timer” on page 4-61
.

E054
Profibus SPC
has taken itself
off-line

Profibus SPC has taken itself off-line

Cycle the Apex
unit’s power off and
on and reestablish
communications
between the master
and the slave.

E055
Profibus
memory buffer
overflow

Profibus memory buffer overflow

Increase the time
between packets
being sent to the unit
via the Profibus
master. See “Host
Port—Profibus” on
page 4-58.

E059
Profibus master
released slave

Profibus master released slave

To recover from the
“off state,” have a
Profibus master
establish
communications with
the Apex unit and
send a “master reset”
to clear the Apex
unit’s display. See
“Host Port—
Profibus” on
page 4-58.

E101
Measurement
PCB ID is
incorrect

This indicates a configuration error.

Call AE Global
Support.