Line frequency, 47 to 63 hz, Line current – Apex Digital 5708009-C User Manual
Page 38: Output electrical specifications, Table 3-3. output specifications, Regulation modes, Output frequency, 0—n/a, 3—13.56 mhz, ±0.005, Output electrical specifications -6

3-6
5708009-C
Advanced Energy
®
Output Electrical Specifications
Table 3-3 describes the output specifications for the Apex generator.
Line frequency
47 to 63 Hz
Line current
Typical A/
φ and circuit breaker rating for units with
208 Vac nominal input (PIN position 3, options 0 and 3)
•
1500 W/13.56 MHz—9 A/
φ; 15 A breaker
•
3000 W/13.56 MHz—14 A/
φ; 25 A breaker
•
5500 W/13.56 MHz—25 A/
φ; 40 A breaker
Typical A/
φ and circuit breaker rating for units with
400 Vac nominal input (PIN position 3, option 1)
•
3000 W/13.56 MHz—9 A/
φ; 15 A breaker
•
5500 W/13.56 MHz—15 A/
φ; 25 A breaker
Table 3-2. Input Power Specifications (Continued)
Description
PIN Option and Specification
Table 3-3. Output Specifications
Description
PIN Option and Specification
Regulation modes
•
Forward power
•
Load power
•
External feedback (dc bias, for example)
Output frequency
Note: Varies according to the
option defined by PIN
position 1.
0—N/A
3—13.56 MHZ, ±0.005%