Table 4-17. response message, Forward power sense ai (lsb), Forward power sense ao (msb) – Apex Digital 5708009-C User Manual

Page 124: Reflected power sense a1 (lsb), Reflected power sense ai (msb), Not used ai (lsb), Not used ai (msb), Ints, Response message -78

background image

4-78

5708009-C

Advanced Energy

®

Forward Power Sense 0 to 10 V; 10 V = maximum rated power linear
Reflected Power Sense 0 to 10 V; 10 V = maximum reflected power linear
POS = Power on Status; 1 = power output ON, 0 = power output OFF
SPS = Setpoint Status; 1 = setpoint reached, 0 = setpoint not reached
TS = Temperature Status; 1 = GOOD, 0 = OVERTEMP
INTS = Interlock Status; 1 = satisfied, 0 = open

Note: The 16-bit AO is shifted right four bits and the remaining first four bits are

filled with 0s. This changes the 16-bit AO to a 12-bit AO with a value of
10 V = OFFF

hex

.

Note: Readbacks exceeding OFFF

hex

are limited to OFFF

hex

.

Table 4-17. Response Message

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

0

Forward Power Sense AI (LSB)

1

0

0

0

0

Forward Power Sense AO

(MSB)

2

Reflected Power Sense A1 (LSB)

3

0

0

0

0

Reflected Power Sense AI

(MSB)

4

Not Used AI (LSB)

5

0

0

0

0

Not Used AI (MSB)

6

Not Used AI (LSB)

7

0

0

0

0

Not Used AI (MSB)

8

INTS

TS

SPS

POS