5708009-C

4-55

Apex 1 to 5.5 kW Generator

201

report unit

on events

Reports a count of unit on events

Note: The response contains 4 bytes which

represent a 32-bit count of events (LSB
first).

4 data bytes
32-bit value

202

report

output on

events

Reports a count of output on events

Note: The response contains 4 bytes which

represent a 32-bit count of events (LSB
first).

4 data bytes
32-bit value

203

report

overtemp

events

Reports a count of overtemp events

Note: The response contains 4 bytes which

represent a 32-bit count of events (LSB
first).

4 bytes

32 bit value

205

read run

time

Requests the amount of time (in seconds) that
the generator was producing output.

Note: The response contains 4 bytes which

represent a 32-bit time (LSB first). It
returns the amount of time in seconds
that the unit was producing output.

4 data bytes
32-bit value

206

read total

energy

output

Requests the total amount of energy (in kWh)
delivered by the generator.

Note: The response contains 4 bytes which

represent a 32-bit time (LSB first). It
returns the amount of energy in kilo
watt hours delivered by the unit.

4 data bytes
32-bit value

210

report fault

warnings

and

shutdowns

Returns faults, warnings, and shutdowns

Note: The response contains 1 data byte

which represents fault warnings and
shutdowns.

bit 0 indicates ripple warning
(0 = inactive, 1 = active)

bit 1 indicates ripple failure
(0 = inactive, 1 = active)

bit 2 indicates temperature rate failure
(0 = inactive, 1= active)

1 data byte

8-bit value

Table 4-6. Host Port Commands for RS-232 with AE Bus (Continued)

Command

Description

Number of

Host Data

Bytes

Number of

Response

Data Bytes