5708009-C

4-71

Apex 1 to 5.5 kW Generator

185

read

allowable

deviation

Requests what percentage the generator can be
out of setpoint before it starts the out-of-
setpoint timer (set with CMD 16).

0

1 data bytes

8-bit value

198

read

mainframe

software

revision

level

Requests the revision level of the mainframe
software. The returning packet contains three
ASCII characters—one letter, followed by a
two-digit number. Used in conjunction with
CMD 130 to obtain the version/revision of the
mainframe software.

0

3 data bytes

3 ASCII

characters

205

read run

time

Requests the amount of time (in seconds) that
the generator was producing output.

0

4 data bytes
32-bit value

206

read total

energy
output

Requests the total amount of energy (in kWh)
delivered by the generator.

0

4 data bytes
32-bit value

Table 4-11. Profibus Host Port Commands (Continued)