Digital input, See wiring diagram 4-5, Analog input – Apex Digital 5708009-C User Manual

Page 51: See wiring diagram 4-3

background image

5708009-C

4-5

Apex 1 to 5.5 kW Generator

4

17

RF PWR ON

Digital

input

When a positive voltage between
4 and 30 V is applied to this pin
RF output is enabled. Once the
output is ON, a voltage of 1.5
Vdc or less disables the RF
output.

See Wiring Diagram 4-5.

Note: The interlocks must be

satisfied and the setpoint
must be within the Output
power range before unit
will deliver power. See
Table 3-3. on page 3-6 for
the Output power range
specification.

5

18

SETPOINT

Analog

input

This pin linearly controls the RF
output of the generator.

0 to 10V = 0 to maximum rated
power output as defined by
configuration PIN position 2 in
Table 1-1.

See Wiring Diagram 4-3.

Note: Setpoint must be greater

than 1% of full rated
output before unit will
deliver power.

Table 4-1. User Port 25-Pin APEX Standard Pin Descriptions (Continued)

Signal

Pin

Return

Pin

Name

Signal

Type

Description