Environmental specifications, Table 3-6. climatic specifications, Class 3k3 – Apex Digital 5708009-C User Manual
Page 46: 5˚c to +40˚c, 41˚f to +104˚f, Class 3k2, 10% to 85% 1, 2 g/m3 to +25 g/m3, 80 kpa to 106 kpa, Class 1k4

3-14
5708009-C
Advanced Energy
®
ENVIRONMENTAL SPECIFICATIONS
Table 3-6 and Table 3-7 provide climatic and other environmental specifications for
the Apex generator.
Table 3-7 shows other environmental specifications for the Apex generator.
Table 3-6. Climatic Specifications
Temperature
Relative Humidity
Air Pressure
Operating
Class 3K3
5
°
C to +40
°
C
+41
°
F to +104
°
F
Class 3K2
10% to 85%
+2 g/m
3
to +25 g/m
3
Class 3K3
80 kPa to 106 kPa
800 mbar to 1060 mbar
(approximately 2000 m
above sea level)
Storage
Class 1K4
-25
°
C to +55
°
C
-13
°
F to +131
°
F
Class 1K3
5% to 95%
+1 g/m
3
to +29 g/m
3
Class 1K4
80 kPa to 106 kPa
800 mbar to 1060 mbar
(approximately 2000 m
above sea level)
Transportation
Class 2K3
-25
°
C to +70
°
C
-13
°
F to +158
°
F
Class 2K3
95%
2
+60 g/m
3
Class 2K3
66 kPa to 106 kPa
660 mbar to 1060 mbar
(approximately 3265 m
above sea level)
1
Non-condensing
2
Maximum relative humidity when the unit temperature slowly increases, or when the unit
temperature directly increases from -25°C to +30°C
3
Maximum absolute humidity when the unit temperature directly decreases from +70°C to
+15°C
Table 3-7. Environmental Specifications
Description
Specification
Overvoltage
Category II
Pollution Degree
2