Returns the condensed snapshot of generator data, 0,1: forward power with bias correction, 2,3: reflected power with bias correction – Apex Digital 5708009-C User Manual
Page 103: 4,5: delivered power with bias correction, 6,7 user setpoint, Regulation mode (see command 3 for definition), 15,16: dc voltage, 17,18: dc current, 19 to 22: unused, Apex with vi measurement data point definitions

5708009-C
4-57
Apex 1 to 5.5 kW Generator
219
report
condensed
snapshot of
generator
data
Returns the condensed snapshot of generator
data
Note: The response contains 2 sets of
responses for APEX with Directional
Coupler and VI System.
For Directional coupler the data points
are:
• 0,1: Forward Power with Bias
Correction
• 2,3: Reflected Power with Bias
Correction
• 4,5: Delivered Power with Bias
Correction
• 6,7 User Setpoint
• 8: Regulation Mode (see command 3 for
definition)
• 9 to 12: Process Status (see command
162 for definition)
• 13,14: Cold Plate Temperature (see
command 228 for definition)
• 15,16: DC Voltage
• 17,18: DC current
• 19 to 22: Unused
APEX with VI Measurement data point
definitions:
• 0,1: Real Power with Bias Correction
• 2,3: Imaginary Power with Bias
Correction’
• 4,5:VSQ with Bias Correction
• 6,7: User Setpoint
• 8: Regulation Mode (see command 3 for
definition)
• 9 to 12: Process Status (see command
162 for definition)
• 13,14: Cold Plate Temperature (see
command 228 for definition)
• 15,16: DC Voltage
• 17,18: DC Current
Table 4-6. Host Port Commands for RS-232 with AE Bus (Continued)
Command
Description
Number of
Host Data
Bytes
Number of
Response
Data Bytes