Rmon menu – Allied Telesis AT-VIEW PLUS 2.4 DEVICE MANAGEMENT User Manual
Page 67
Allied Telesyn
AT-VIEW PLUS
DEVICE MANAGEMENT
Note
- It may take some time to retrieve Forwarding Database information. As a result, all
the Forwarding Database parameters may reflect the value 'retry over occurred'. To avoid
this, click on File -> Property -> Polling options and set the Polling Interval parameter to 25
seconds or longer.
Discard/Aging Time Info
Displays information about the number of address entries that were learned but discarded
because either there was a lack of memory or the entry's aging timer expired.
Spanning Tree Info
Displays spanning tree parameters such as spanning tree status and spanning tree version.
Note
- When setting the Spanning Tree Status parameter to 'enabled', connection to the AT-
8400 is temporarily lost. As a result, the following error message appears: "The error
occurred with 'Set' operation. Error: time out occurred.".
Note
- Setting the value of the Spanning Tree Version parameter to 'stp' will result in a
permanent loss of connection. To re-establish connection, restart the device.
Statistics
Displays statistics about frames received/transmitted on the switch's ports.
Note
- Ports are numbered continuously from top to bottom, across all installed line cards,
starting from the leftmost line card all the way through the rightmost line card.
RMON Menu
From the RMON menu you can view and edit the RMON MIB.
Statistics
Displays traffic statistics in the network segment.
History Control Table
Displays the RMON History table.
Note
- The current firmware version does not support the "historyControlTable" MIB object
of RFC1757. As a result, AT-View Plus Device Manager displays the error message "Failed
to get MIB data." when the History Control Table option is selected from the RMON menu.
Alarm Table
Displays the RMON Alarm table.
Event Table
Displays the RMON Event table.
PN 613-50507-00 Rev D
Page 67 of 253