Deleting a view table entry – Allied Telesis AT-S63 User Manual
Page 217

AT-S63 Management Software Web Browser Interface User’s Guide
Section II: Advanced Features
217
Volatile
Select this storage type if you do not want the ability to save an
entry in the View Table. After making changes to a View Table
entry with a Volatile storage type, Save Changes does not appear
on the General tab.
NonVolatile
Select this storage type if you want the ability to save an entry in
the View Table. After making changes to a View Table entry with a
NonVolatile storage type, Save Changes appears on the General
tab. Allied Telesyn recommends this storage type.
Note
The Row Status parameter is a read-only field in the web browser
interface. The Active value indicates the SNMPv3 View Table entry
takes effect immediately.
10. Click Apply to update the SNMPv3 View Table.
11. To save your changes, return to the General tab and click Save
Changes.
Deleting a View
Table Entry
To delete an entry in the SNMPv3 View Table, perform the following
procedure:
1. From the home page, select Configuration.
The Configuration System page is displayed with the General tab
selected by default, as shown in Figure 5 on page 40.
2. Select the SNMP tab.
The SNMP tab is shown in Figure 69 on page 205.
3. In the SNMPv3 section, click the button next to Configure View
Table and then click Configure.
The SNMPv3 View Table tab is shown in Figure 73 on page 215.
4. Click the button next to the View Table entry that you want to delete
and then click Remove.
A warning message is displayed.
5. Click OK.
6. To save your changes, return to the General tab and click Save
Changes.