Asynchronous port – Allied Telesis AR700 SERIES Software Release 2.7.1 User Manual
Page 66

66
AR700 Series Router User Guide
Software Release 2.7.1
C613-02047-00 REV A
To display the modules in the router that are configured to use an Ethernet
interface, and the encapsulations used on an interface, enter the command:
show eth=n configuration
where n is the number of the Ethernet interface.
For more information about Ethernet interfaces and encapsulations, see the
Interfaces chapter in the Software Reference.
Asynchronous Port
Asynchronous ports are normally used to connect a terminal to the router for
configuration purposes. The default values for configurable parameters are
modified by entering the command:
set asyn=port-number option
The factory default settings for asynchronous ports are shown in
.
For more information about asynchronous ports, see the Hardware Reference
or the Interfaces chapter in the Software Reference.
Table 8: Factory defaults for configurable parameters for asynchronous ports.
Option
Default setting
ATTENTION
BREAK
CDCONTROL
IGNORE
DATABITS
8
DEFAULTSERVICE
FALSE
DTRCONTROL
ON
ECHO
ON
FLOW
HARDWARE
HISTORY
30
INFLOW
HARDWARE
IPADDRESS
NONE
IPXNETWORK
NONE
MAXOQLEN
0 (Unrestricted)
MTU
1500
NAME
Asyn #
OUTFLOW
HARDWARE
PAGE
22
PARITY
NONE
PROMPT
DEFAULT (CMD>)
SECURE
ON
SERVICE
NONE
SPEED
AUTO
STOPBITS
1