10. CONTROL INPUTS:
Programmable User Inputs (4):
USR INP 1 to 3: Internal 10 K
W pull-up to +5 VDC, V
IL
= 1.5 V
MAX
; V
IH
=
3.5 V
MIN
, response time = 30 msec typical, 100 msec max. (count rate
dependent).
USR INP 4/INH: Internal 10 K
W pull-up to +5 VDC, V
IL
= 1.5 V
MAX;
V
IH
= 3.0 V
MIN
, response time = 30 msec typical, 100 msec max.
(count rate dependent).
INHIBIT Response time = 50
msec max.
User Inputs Programmed for Binary Message Request: Debounce =
100 msec. (Binary Message Request Inputs must be stable for 100
msec. before a message is requested).
11. SERIAL COMMUNICATIONS:
Type: Jumper selectable RS-485 or RS-232.
Can connect up to 32 units when using RS485 interface.
Baud Rate: Programmable from 1200 to 9600.
Maximum Addresses: Programmable from 00 to 99.
(Actual number on a line is limited by hardware specifications)
Transmit Delay: Programmable for 0.002 or 0.100 second.
Data Format: 10 Bit Frame; 1 start bit, 7 or 8 data bits, 1 or no parity bit, and 1
stop bit. Parity is programmable for either ODD (7 data bits), EVEN (7 data
bits), or NO Parity (8 data bits).
12. OUTPUT(S):
Solid-State: Current sinking NPN open collector transistor. V
CE
= 1.1 V
SAT
@
100 mA max. V
OH
= 30 VDC max. (Internal Zener Diode Protection).
Relay(s): Mounted on field-replaceable P.C. board. Form C contacts rated
at 5 amps @ 120 VAC/240 VAC or 28 VDC (resistive load), 1/8 H.P. @
120 VAC (inductive load). The operate time is 5 msec nominal and the
release time is 3 msec nominal.
Programmable Timed Output(s): Programmable time ranges from 0.01
to 99.99 seconds, ±0.05% - 11 msec. max.
Count Boundary Output Response Time: 10 msec nominal.
Output Time Required to Request Message: 50 msec.
13. ENVIRONMENTAL CONDITIONS:
Operating Temperature: 0 to 50°C
Storage Temperature: -40 to 80°C
Operating and Storage Humidity: 85% max. max. relative humidity
(non-condensing) from 0°C to 50°C.
Vibration According to IEC 68-2-6: Operational 5 to 150 Hz, in X, Y, Z
direction for 1.5 hours, 2 g.
Shock According to IEC 68-2-27: Operational 20 g (10 g relay), 11 msec
in 3 directions.
Altitude: Up to 2000 meters
14. CERTIFICATIONS AND COMPLIANCES
SAFETY
IEC 6 1 0 1 0 -1 , EN 6 1 0 1 0 -1 : S a f e t y req u i remen t s f o r e l e c t ric a l
equipment for measurement, control, and laboratory use, Part 1.
IP65 Enclosure rating (Face only), IEC 529
Type 4X Indoor Enclosure rating (Face only), UL50
ELECTROMAGNETIC COMPATIBILITY
Immunity to EN 50082-2
Electrostatic discharge
EN 61000-4-2 Level 2; 4 Kv contact
Level 3; 8 Kv air
Electromagnetic RF fields
EN 61000-4-3 Level 3; 10 V/m
80 MHz - 1 GHz
Fast transients (burst)
EN 61000-4-4 Level 4; 2 Kv I/O
1
Level 3; 2 Kv power
RF conducted interference
EN 61000-4-6 Level 3; 10 V/rms
1
150 KHz - 80 MHz
Power
frequency magnetic fields EN 61000-4-8 Level 4; 30 A/m
Emissions to EN 50081-2
RF interference
EN 55011
Enclosure class A
Power mains class A
Note:
1. When the unit is DC powered from terminal TBA pin 5 (common) and
terminal TBA pin 3 (DC OUT/IN) a power line filter was installed, RLC
#LFIL0000 or equivalent, so as not to impair the function of the unit.
Refer to EMC Compliance Installation for additional information
15. CONSTRUCTION: High impact plastic case with clear viewing window.
The unit is rated for NEMA 4X/IP65 indoor use. Installation Category II,
Pollution Degree 2 Panel gasket and mounting clips included.
16. WEIGHT: 1.5 lbs. (0.68 Kg)
-58-