Program code number (pro.code) 11 – Red Lion LEGEND User Manual
Page 13
PROGRAM CODE NUMBER (PRO.CODE)
In two of the Program Disable states, it is necessary to enter the PRO.CODE
number before gaining access to the programming menus. The default value for
the code is “00”, but should be programmed differently (See Program Options
Module). This helps prevent inadvertent entry into the unit programming menus.
The PRO.CODE prompt is viewed when PROGRAM MODE is displayed and
the enter key is pressed. At this time, the Code Number must be entered using the
arrow keys. If the wrong code number is entered, the operator will NOT be able to
enter the programming loop and the unit returns to the main display loop.
FRONT PANEL ACCESSIBLE FUNCTIONS WITH PROGRAM
DISABLE
The Legend Plus has several ways to limit the programming of parameters from
the front panel keypad. The Operator Access section of the Program Options
Module is used with the Program Disable (PGM.DIS.) DIP switch and a User Input
selected for PGM.DIS to limit programming. To enter the programming loop, a
code number may need to be entered, depending on the Program Disable setting.
Only an external User Input can be selected for Program Disable. The following
list describes the possible program disabling settings.
PGM.DIS.
SWITCH
USER INPUT
TERMINAL
PROGRAM
CODE
NUMBER
ACTION
OFF
INACTIVE or Not
Programmed for PGM.DIS
ALL
All programming enabled.
OFF
ACTIVE
0 to 98
Operator Accessible Functions
Enabled, Programming Loop
Accessible via code number.
OFF
ACTIVE
99
O p e r a t o r A c c e s s i b l e F u n c t i o n s
Enabled, Programming Loop Disabled.
ON
INACTIVE or Not
Programmed for PGM.DIS
0 to 98
Operator Accessible Functions
Enabled, Programming Loop
Accessible via Code number.
ON
INACTIVE or Not
Programmed for PGM.DIS
99
O p e r a t o r A c c e s s i b l e F u n c t i o n s
Enabled, Programming Loop Disabled.
ON
ACTIVE
ALL
O p e r a t o r A c c e s s i b l e F u n c t i o n s
D i s a b l e d ,
P r o g r a m m i n g
L o o p
Disabled.
Note: If the User Input, set for PGM.DIS., is changed to another function, make
sure the User Input is not low (active). If the input is low when the function is
changed, the program disable function is still active for the User Input.
-11-