Preset or Counter Load modes, it would apply to preset value between 0 to 6
less than the Preset 2 value (when positive).

2. For Auto Reset modes, no other count presets should be set to the same count

value at which Auto Reset occurs (Preset 2 or Zero for Reset to Preset or
Counter Load mode). If they are, only the auto reset output will activate. If the
process counter is set to Auto Reset at OUT1 & 2, and other Presets are the same
as Preset 2 (or Zero for Reset to Preset mode), only Output 2 will activate. If the
unit is set to Auto Reset at OUT1, only Outputs 1 and 2 will activate.

BATCH RESET ACTION (BAT. RST)

The Batch count display can be reset to Zero, Preset 4, or to the Counter Load

value. The display can be reset automatically or by a User Input. Reset by User
Input can be a Maintained or Momentary reset (See Program User Module for
details). Automatic reset is covered in the next section.

TO ZERO

The Batch Counter Display value returns to zero.

TO P4 (PRESET 4)

The Batch Counter Display value returns to the Preset 4 value. Output 4

triggers when the count reaches zero.

TO CT LD (COUNTER LOAD)

The Batch Counter Display value returns to the Counter Load value.

Note: The Counter Load reset action should be programmed for only one count

display, either the process count or the batch count.

BATCH AUTOMATIC RESET (B AUTO. RS)

The Automatic reset mode can be enabled or disabled. The Batch Counter display

automatically resets to the programmed reset action, when one of the automatic reset
modes is selected. A manual reset by a User Input causes the count to reset regardless
of the automatic reset mode. The following choices are available:

OUT3 (Reset at Beginning Of Output 3)

The batch counter resets when the count equals the preset 3 value. Output 3

can be timed or latched.

OUT3END (Reset at End Of Timed Output 3)

The batch counter resets after output 3 has timed out.

OUT4 (Reset at Beginning Of Output 4)

The batch counter resets when the count equals preset 4, or zero (Reset to P4).

Output 4 can be timed or latched.

OUT4END (Reset at End Of Timed Output 4)

The batch counter resets after output 4 has timed out.

OUT3&4 (Reset at Beginning Of Output 3 or Output 4)

The batch counter resets when the count equals preset 3, preset 4, or zero

(Reset to P4). Outputs 3 and 4 can be Timed or Latched.

OUT3&4E (Reset at End Of Timed Output 3 or Output 4)

The batch counter resets after output 3 or output 4 has timed out.

TOTAL RESET ACTION (TOT. RST.)

The Total count display can be reset to Zero, or to Preset 3. Output 3 must be set to

Total for P3 to be selected. The method of reset is by User Input. The User Input can
be set for a Momentary or Maintained reset (See Program User Module for details).

TO ZERO

The Total Count Display value returns to Zero. In this mode, the Total count

direction is up.

TO P3 (PRESET 3)

The Total Count Display value returns to the Preset 3 value. Output 3 triggers

when the count reaches zero. In this mode, the Total count direction is down.