Program display module 28, Displays 1 to 4 28, Scroll speed (scro.spd) 28 – Red Lion LEGEND User Manual
Page 30: Display intensity (dsp.level) 28, Custom display lines (cust.dsp.1 / cust.dsp.2) 28, Mnemonic 28
PROGRAM DISPLAY MODULE
DISPLAYS 1 TO 4
The four indication displays are programmed individually. Each line of each
display can be configured to show a value mnemonic, a numeric value, the output
status, a preset value, the counter load value, or a custom display line. Each
display can be programmed to be Green or Red on Dual Color models. The full
value mnemonics are factory set to:
RATE
PEAK
VALLEY
PROCESS
BATCH
TOTAL
The first character of the full mnemonic is displayed to the left of the appropriate
numeric value if the other line is not programmed to display the full mnemonic. The
mnemonic for the Total is not shown in the display, since the total count requires
eight digits. For rate peak and rate valley displays, the abbreviated mnemonic is the
first character of the full rate mnemonic, followed by the first character of the full
peak or valley mnemonic. The following is a list of the single or dual character
mnemonics that are displayed for the factory set full mnemonics:
SCROLL SPEED (SCRO.SPD)
The indication displays can be set to scroll automatically at a 2.5 or 5 second
rate. The displays can be selected not to scroll, in which case the up and down
arrow keys are used to scroll through the displays.
DISPLAY INTENSITY (DSP.LEVEL)
The brightness of the backlighting can be adjusted from 1 to 5, with 5 as the
brightest. On dual color models, there is a separate adjustment for each color.
CUSTOM DISPLAY LINES (CUST.DSP.1 / CUST.DSP.2)
The Legend Plus has two Custom Display Lines which allow the user to specify
the number of digits of a value to be displayed on the line, along with any
alpha-numeric prefix or suffix. This feature has the same available characters as
messages and program mnemonics. The numeric digit positions are indicated by
pressing F1 and ENT at the desired display position. For a complete list of characters
and text editing key functions, see Program Messages Text Editing section.
MNEMONIC
Allows the user to modify main display values (RATE, PROCESS, BATCH,
etc.) to display the value of their choice. For example, the value “RATE” can be
changed to read “SPEED”. See Program Messages Text Editing section for a
complete listing of available characters and text editing commands.
-28-
R
-
Indicates the Rate Value.
Rp
-
Indicates the Rate Peak Value.
Rv
-
Indicates the Rate Valley Value.
P
-
Indicates the Process Counter Value.
B
-
Indicates the Batch Counter Value.
O -1 2 3 4
-
Indicates output status:
The numeric digits show which outputs are on.
When the output is off, the digit is replaced by a small box (
n
).
P1
-
Indicates Preset 1 Value.
P2
-
Indicates Preset 2 Value.
P3
-
Indicates Preset 3 Value.
P4
-
Indicates Preset 4 Value.
CL
-
Indicates Counter Load Value.